Medical Device Calibration
Biomedical and patient care equipment calibration meeting FDA, IEC 62353, and AAMI standards.
Accredited Scope of Calibration
Techmaster’s medical device calibration scope supports hospitals, clinics, and medical device manufacturers with accredited calibrations that satisfy FDA 21 CFR Part 820 and Joint Commission requirements.
ISO/IEC 17025 Accredited — ANAB AC-1736
Techmaster Electronics is accredited by ANAB (ANSI National Accreditation Board) under ISO/IEC 17025:2017 for calibration services. Our scope of accreditation covers the parameters listed below with stated measurement uncertainties.
| Parameter | Range | Best Measurement Uncertainty |
|---|---|---|
| Patient Simulator ECG | 0.5 mV to 5 mV (0.5 to 300 BPM) | 1% to 2% |
| SpO2 Simulation | 70% to 100% saturation | 1% to 2% |
| NIBP Simulation | 0 to 300 mmHg | 1 mmHg to 3 mmHg |
| Electrical Safety (Leakage) | 1 μA to 5 mA | 2% to 5% |
| Defibrillator Energy | 1 J to 360 J | 2% to 5% |
| Infusion Pump Flow Rate | 0.1 mL/hr to 999 mL/hr | 1% to 3% |
| Electrosurgical Power | 1 W to 400 W | 3% to 5% |
Instruments We Calibrate
We calibrate a wide range of medical device calibration instruments. Every calibration includes a detailed certificate with measurement data, traceability information, and as-found / as-left values.
Patient Simulators (ECG, SpO2, NIBP, IBP)
NIST-traceable calibration with accredited measurement uncertainty per ISO/IEC 17025.
Electrical Safety Analyzers
NIST-traceable calibration with accredited measurement uncertainty per ISO/IEC 17025.
Defibrillator Analyzers
NIST-traceable calibration with accredited measurement uncertainty per ISO/IEC 17025.
Infusion Pump Analyzers
NIST-traceable calibration with accredited measurement uncertainty per ISO/IEC 17025.
Electrosurgical Analyzers
NIST-traceable calibration with accredited measurement uncertainty per ISO/IEC 17025.
Ventilator Testers
NIST-traceable calibration with accredited measurement uncertainty per ISO/IEC 17025.
Thermometer Calibrators
NIST-traceable calibration with accredited measurement uncertainty per ISO/IEC 17025.
Biomedical Multimeters
NIST-traceable calibration with accredited measurement uncertainty per ISO/IEC 17025.
Why Choose Techmaster
ISO/IEC 17025 Accredited
ANAB-accredited laboratory with documented measurement uncertainties and full NIST traceability for every calibration.
35+ Years of Expertise
Calibration engineers with decades of hands-on experience across military, aerospace, medical, and industrial applications.
On-Site & Lab Service
Flexible service options including in-lab calibration at 4 US locations and on-site calibration at your facility nationwide.
Ready to Schedule Medical Device Calibration?
Contact Techmaster for a free quote. Fast turnaround, competitive pricing, and accredited certificates for every calibration.