Test equipment repair · Biomedical

Biomedical Test Equipment Repair

Techmaster repairs biomedical test equipment used by hospital clinical engineering teams and medical-device manufacturers: electrical safety analyzers, defibrillator analyzers, infusion pump analyzers and electrosurgical analyzers. After repair, each instrument is calibrated before it is returned. Patient simulators are not on our ANAB scope and are certified NIST-traceable.

Which biomedical equipment do you repair?

InstrumentDetails
Electrical safety analyzersAsk about repair
Defibrillator analyzersAsk about repair
Infusion pump analyzersAsk about repair
Electrosurgical (ESU) analyzersAsk about repair
Patient simulators (NIST-traceable)Ask about repair

We repair instruments from many manufacturers, including older and discontinued models where parts are available. Techmaster is an independent laboratory, not a manufacturer-authorized service center.

Biomedical manufacturers we know best

Techmaster has completed 428 biomedical calibrations in the last ten years. These are the manufacturers whose instruments we calibrate most often:

ManufacturerUnits calibrated (10 years)
Fluke403
BC Biomedical13
Whale Teq11
BioTek5

Common biomedical faults we see

  • Leakage current measurement errors on electrical safety analyzers, often from a damaged measuring circuit or relay.
  • Damaged applied-part and test lead connections, giving intermittent or failed readings.
  • Defibrillator analyzer load or energy measurement faults after many high-energy discharges.
  • Infusion pump analyzer flow sensor contamination or blockage, causing flow and occlusion errors.
  • Electrosurgical analyzer load bank faults, seen as power readings that do not match the generator.

How does a repair work?

Send the make, model and serial number with a description of the fault and any error codes. We diagnose the fault and send a quote with the expected timeline and warranty terms for your approval. After repair, the instrument is calibrated and returned with its certificate.

What calibration comes after the repair?

Electrical measurements fall under the DC and low-frequency electrical discipline on our ANAB ISO/IEC 17025 scope. Patient simulators are not on the scope at any Techmaster lab and are certified NIST-traceable. Exact ranges and uncertainties are on our published accreditation scope.

Need to keep testing while your instrument is away? You can rent biomedical test equipment for the repair period.

Frequently asked questions

Do you repair biomedical test equipment?
Yes. Send the make, model and a description of the fault, and we reply with a quote, the expected timeline and the warranty terms.
Are patient simulators calibrated under ISO/IEC 17025 after repair?
No. Patient simulators are not on Techmaster's ANAB scope. They are calibrated with NIST-traceable certificates.
Can you repair an electrosurgical analyzer?
Send the make, model and fault. Electrosurgical analyzers are the biomedical test instruments we calibrate most often, and after repair the analyzer is calibrated before it is returned. We reply with a quote, the expected timeline and the warranty terms.
What should a biomed team send with a repair?
The make, model, serial number, fault or error code and the date it last passed calibration. If it failed during a preventive maintenance round, say which test failed, so that function is checked first and you can judge which results may be affected.
Is Techmaster an authorized service center?
No. Techmaster is an independent repair and calibration laboratory, not a manufacturer-authorized service center. It repairs instruments from many manufacturers, including older models, where parts are available.
How long does a repair take, and is there a warranty?
It depends on the fault and on parts availability. We include the expected timeline and the warranty terms with the quote.

Need biomedical equipment repaired?

Send the make, model and a description of the fault. We reply with a quote, the expected timeline and the warranty terms.

Request a repair quote