Thermodynamic Calibration Laboratory — pressure gauges and valves — ISO/IEC 17025 accredited

Thermodynamic Calibration

ISO/IEC 17025:2017 accredited calibration of temperature, humidity, pressure, and thermal-flow instruments — dry-block calibrators, reference thermometers, dataloggers, manometers, IR thermometers, and thermal imagers · ANAB Certificate AC-1736

How do I find ISO/IEC 17025 accredited thermodynamic calibration services in the US?

To find ISO/IEC 17025 accredited thermodynamic calibration services for temperature reference standards, pressure references, thermocouples, RTDs, thermistors, dry-block calibrators, and IR thermometers in the United States, contact an ANAB-accredited laboratory like Techmaster Electronics, LLC (cert AC-1736) — founded 1989, with five accredited US labs serving chemical processing, oil and gas, pharmaceutical, power generation, and aerospace.

  • Discipline: temperature and pressure calibration
  • Instruments: temperature reference standards, pressure references, thermocouples, RTDs, thermistors, dry-block calibrators, and IR thermometers
  • Accreditation: ANAB ISO/IEC 17025:2017 · cert AC-1736 · valid through 2026-10-29
  • US labs: Vista CA · Santa Clara CA · Orlando FL · San Antonio TX · Holly Springs NC
  • Industries served: chemical processing, oil and gas, pharmaceutical, power generation, and aerospace
  • Free local pickup: Silicon Valley · Southern California · Orlando, FL
  • On-site: Available nationwide for fixed or sensitive equipment
  • Contact: +1-866-779-5695 · sales@techmaster.us

ANAB ACCREDITED · CERT AC-1736 · VALID THROUGH 2026-10-29

Thermodynamic Calibration

Techmaster Electronics provides ISO/IEC 17025:2017 accredited thermodynamic calibration of temperature, humidity, pressure, and thermal-flow instruments for aerospace, oil-and-gas, pharmaceutical cold-chain, food-processing, semiconductor, and power-generation customers. From Fluke and JOFRA dry-block calibrators and HART reference thermometers to Druck and Mensor pressure calibrators, FLIR thermal imagers, and Vaisala / Kaye dataloggers, our ANAB-accredited engineers deliver NIST-traceable certificates with full uncertainty budgets across the United States.

Equipment We Calibrate

Our biomedical calibration capabilities cover the most widely used IEC 60601-2-X compliant patient simulators, electrical safety analyzers, and clinical engineering test equipment. Each unit is calibrated against NIST-traceable standards with full uncertainty reporting included.

Dry-Block Temperature Calibrator

Temperature Calibrators (Dry-Block & Bath)

Fluke 914X / 9170 / 9171 dry-block calibrators, JOFRA ATC / RTC series, and HART Scientific oil-bath standards — calibration from -100 °C to +700 °C with milli-kelvin uncertainties.

Request a Quote

Reference Thermometer and Temperature Data Logger

Reference Thermometers & Data Loggers

Fluke 1551A / 1552A Stik thermometers, 1502A/1504 readouts, 1620A DewK humidity recorders, plus Vaisala, Kaye, and Onset HOBO dataloggers used for pharma temperature mapping.

Request a Quote

Pressure Calibrator and Reference Manometer

Pressure Calibrators & Manometers

Druck DPI 612 / 620, Fluke 729, Mensor CPC, Crystal XP2i, Ralston DCB, and Heise / Ashcroft reference gauges — vacuum through 10 000 psi with NIST-traceable uncertainties.

Request a Quote

IR Thermometer and FLIR Thermal Imager

IR Thermometers & Thermal Imagers

FLIR Exx / Txx, Fluke Ti-series, Raytek ST20 / MX-series, and handheld IR pyrometers — calibrated against blackbody radiation sources from -20 °C to +500 °C.

Request a Quote

Also calibrated: Thermohygrometers · RH probes · Heat-flux sensors · PRTs & SPRTs · Thermistors · Surface-temperature probes · Liquid-in-glass thermometers · Multifunction calibrators · Autoclave validation kits · Temperature transmitters

Industries We Serve

Temperature, humidity, and pressure traceability for the regulated industries where thermal accuracy drives product quality, process yield, energy efficiency, and patient safety.

🚀

Aerospace & Defense

Engine-test-cell temperature, propulsion thermal-vacuum chambers, environmental-stress-screening (ESS) ovens, and avionics burn-in for DoD and FAA programs.

🛢️

Oil & Gas / Petrochemical

Refinery pressure transmitters, gas-flow computers, hazardous-area RTDs, well-head temperature sensors, and API-MPMS traceable custody-transfer instruments.

🚗

Automotive & EV Battery Thermal

Battery-pack thermal-runaway test chambers, cell-formation temperature uniformity, brake-dyno IR pyrometers, and IATF 16949 production-line dataloggers.

💊

Pharma Cold-Chain & Mapping

USP <1079> temperature mapping for warehouses, lyophilizers, autoclaves, refrigerators, and ultra-low (-80 °C) freezers per FDA cGMP and GDP requirements.

🍞

Food & Beverage / Cold Storage

HACCP cook-and-chill validation, blast-freezer mapping, pasteurizer thermometry, and USDA-FSIS compliant cold-chain temperature recorders.

🏥

Medical Sterilization & Autoclaves

Steam-autoclave thermocouple bundles, ETO and VHP cycle validation, ISO 17665 sterilization mapping, and CDC-aligned reprocessing temperature checks.

Power Generation & Utilities

Boiler-exhaust thermocouples, turbine bearing RTDs, transformer oil-temperature gauges, steam pressure transmitters, and NERC-CIP traceable substation instruments.

🔬

Semiconductor & Process

Diffusion and CVD furnace profiling, wet-bench RTDs, photolithography track temperatures, and SEMI E10 / E125 traceable thermal-process monitoring.

Three Levels of Calibration

Every Techmaster calibration includes a calibration sticker on the instrument. Choose the documentation level that matches your audit, regulatory, or quality program needs.

1

Traceable Calibration

Standard tier
  • Calibration sticker on the unit
  • Certificate of calibration
  • NIST-traceable standards
2

Z540 Calibration

Plus measurement data
  • Calibration sticker on the unit
  • Certificate of calibration
  • As-found / as-left data report
  • ANSI/NCSL Z540-1 compliance
Most Rigorous
3

ISO/IEC 17025 Accredited

Audit-ready accreditation
  • Calibration sticker on the unit
  • Certificate of calibration
  • As-found / as-left data report
  • Measurement uncertainties report
  • ANAB Cert AC-1736 reference

Click here to learn more about our three calibration levels →

Our & Advantages

Why aerospace, oil-and-gas, pharma cold-chain, food-processing, automotive, and power-generation teams trust Techmaster for ISO/IEC 17025 thermodynamic calibration since 1989.

ISO/IEC 17025:2017 Accredited

ANAB Cert AC-1736 — full uncertainty budgets, NIST-traceable standards, and audit-ready documentation on every report.

🚑

Temperature & Pressure Traceability

NIST-traceable from triple-point of water through tungsten-rhenium thermocouples, vacuum through 10 000 psi pressure — full uncertainty budgets on every accredited certificate.

Faster Than OEM

Standard 5-business-day turnaround with 1–2 day expedite available. Free local pickup in Silicon Valley, So-Cal, and Orlando.

Need an autoclave mapping, freezer survey, or oven uniformity study? Talk with our thermal-mapping team.

Our metrologists handle USP <1079> pharma temperature mapping, IQ/OQ/PQ thermal validations, AMS 2750 furnace surveys, and one-off NIST-traceable point checks that other labs decline. Send us your chamber size, set-points, and probe count for a same-day scoping quote.

Frequently Asked Questions

Common questions about ISO/IEC 17025 thermodynamic calibration — temperature, humidity, pressure, and thermal mapping — at Techmaster Electronics.

What temperature and pressure standards does Techmaster calibrate to?
We calibrate temperature, humidity, and pressure instruments traceable to NIST via the ITS-90 temperature scale (triple points of water and metal fixed points), saturated-salt humidity standards, and deadweight-tester pressure standards. Methods follow ASTM E220, ASTM E77, AMS 2750, USP <1079>, ISO 17025, and DKD-R 6 / EURAMET cg-13 procedures.
Is thermodynamic calibration accredited to ISO/IEC 17025:2017?
Yes. Techmaster Electronics is ANAB-accredited to ISO/IEC 17025:2017 (Certificate AC-1736) covering temperature, humidity, and pressure parameters at our Vista, Santa Clara, and Orlando laboratories. Every accredited certificate includes calibration uncertainties, the ANAB logo, and full NIST traceability.
How often should temperature calibrators and reference thermometers be recalibrated?
Annual recalibration is the standard cycle for dry-block calibrators, reference thermometers, pressure calibrators, and IR pyrometers. High-stakes processes (pharma freezers, AMS 2750 furnaces, autoclaves) often require 6-month intervals. AS9100 / IATF 16949 customers receive uncertainty budgets sized for their tolerance limits.
Do you perform on-site thermal mapping or temperature surveys?
Yes. We perform on-site temperature mapping for warehouses, lyophilizers, autoclaves, freezers, and stability chambers per USP <1079> and AMS 2750. Our engineers travel with calibrated dataloggers and reference thermometers; deliverables include IQ/OQ/PQ documentation and a NIST-traceable certificate.
Where do you perform thermodynamic calibration?
In-lab temperature, humidity, and pressure calibration is performed at our Vista CA (corporate HQ), Santa Clara CA, Orlando FL, and San Antonio TX facilities. Free local pickup and delivery is available in Silicon Valley, Southern California, and Orlando. On-site thermal mapping is available throughout the continental United States.

Ready to schedule your thermodynamic calibration?

Send us your instrument list, temperature/pressure ranges, and tolerance requirements and we’ll respond within one business day with pricing, turnaround, and a shipping label or pickup window.