Patient simulator calibration verifies every physiological signal your simulator produces, ECG, NIBP, SpO2, IBP, temperature, and respiration, against standards traceable to NIST, and documents the results with as-found and as-left data. Techmaster Electronics, founded in 1989, calibrates Fluke ProSim and Pronk simulators with a 5-day standard turnaround, and offers rentals for short-term projects.
Key points
- Fluke ProSim 8, ProSim 4, Pronk SimCube, and other patient simulators serviced
- ECG, NIBP, SpO2, IBP, temperature, and respiration verified with NIST-traceable data
- As-found / as-left data your accreditor and FDA auditor can follow
- Rental options for short-term projects, ask about current availability
- 5-day standard turnaround; 1–2 day expedite on most units
What is patient simulator calibration?
Patient simulator calibration is the verification of the simulated physiological signals a device like the Fluke ProSim 8 generates, heart rate and ECG amplitude, non-invasive blood pressure, oxygen saturation, invasive pressure, temperature, and respiration, against traceable reference standards. It proves the simulator you use to test patient monitors is itself telling the truth.
That matters because the simulator is the reference in every monitor check a biomed team performs. If the simulator drifts, every “passing” monitor inherits the error.
How is a patient simulator calibrated?
Our lab verifies each simulated parameter against NIST-traceable pressure, electrical, and timing standards, checking the values your simulator outputs against the manufacturer’s published specification. Results are recorded parameter by parameter, so the certificate shows exactly what was tested and how it read before and after service.

How often should a patient simulator be calibrated?
Calibrate a patient simulator every 12 months. AAMI-aligned hospital HTM programs and ISO 13485 device manufacturers both audit against a fixed annual cycle, and accreditation surveyors ask for the simulator’s certificate, not just the monitors it tested. Recalibrate after any repair or firmware service.
What gets verified during patient simulator calibration?
ECG rate and amplitude, NIBP pressure accuracy, SpO2 saturation values, invasive blood pressure channels, temperature outputs, and respiration rate, each against the manufacturer’s specification, with NIST-traceable data.

Which patient simulators do you service?
The units our labs see most: Fluke Biomedical ProSim 8 and ProSim 4 vital signs simulators, Pronk SimCube NIBP simulators, and related biomedical test tools, SpO2 pods, IBP simulators, and ECG simulators from Fluke, Pronk, BC Biomedical, and Netech. Repair support is available when a simulator fails self-test.
Can I rent a patient simulator instead?
Yes, rental is one of the most common requests we receive for this category. Biomed teams rent a ProSim 8 or SimCube for a one-week PM sweep, a device manufacturer borrows one for design verification, and field service companies fill program gaps. Ask us about current rental availability and weekly rates when you request a quote.
Which teams need patient simulator calibration?
Hospital HTM departments keep ProSim units on annual certificates because surveyors ask for them. Third-party biomed service companies calibrate rented and owned simulators alike. Device manufacturers, from patient monitoring to surgical robotics, need traceable simulation data behind every verification report.

What documentation do I get?
A NIST-traceable calibration certificate with as-found and as-left data for every parameter tested. Techmaster is an ISO/IEC 17025 accredited laboratory (ANAB Cert. AC-1736); accreditation covers the disciplines on our scope file, and patient simulators are calibrated as traceable calibrations. Tell us the level your quality system requires and we will confirm before work begins.
How fast will I get my simulator back?
Standard turnaround is 5 business days from receipt. Expedited 1–2 business day service is available on most units for a nominal fee. Ship to any of our US labs, or use free local pickup and delivery in Silicon Valley, Southern California, and Orlando, Florida.
Techmaster Electronics, calibration, repair, and rental provider serving the United States, founded 1989. ISO/IEC 17025 accredited laboratory, ANAB Cert. AC-1736. 381,916 calibrations completed across 4,913 manufacturers. Labs in Vista & Santa Clara CA, Orlando FL, San Antonio TX, and Holly Springs NC.
Frequently asked questions
How often should a patient simulator be calibrated?
Every 12 months, and after any repair or firmware service, surveyors ask for the simulator’s certificate, not just the monitors it tests.
Which parameters do you verify on a ProSim 8?
ECG rate and amplitude, NIBP, SpO2, invasive blood pressure, temperature, and respiration, each with NIST-traceable as-found / as-left data.
Can I rent a patient simulator?
Yes. ProSim and SimCube rentals are available for short-term projects, ask about current availability and weekly rates when you request a quote.
Is the calibration ISO 17025 accredited?
Patient simulators are calibrated as NIST-traceable calibrations with full data. Techmaster is an ISO/IEC 17025 accredited lab (ANAB Cert. AC-1736); tell us the level your quality system requires and we will confirm before work begins.
What is the turnaround time?
Standard turnaround is 5 business days. Expedited 1–2 business day service is available on most units for a nominal fee.
More on this from our calibration engineers
- Defibrillator analyzer calibration
- FDA-compliant medical device calibration
- External pacemaker analyzer calibration
- Technology trends in medical device calibration
Ready to schedule? Request a patient simulator calibration or rental quote →
Related services
- Calibration services, the full 12-discipline calibration catalog
- Medical calibration scope, biomedical test equipment we service
- Hospitals & healthcare, how we support HTM teams
- Request a quote