San Antonio Calibration Lab — Texas (formerly Rothe)

May 10, 2026

Note on particle counters: This page is for general information only. Techmaster does not calibrate particle counters of any make or model, and particle counters are not on our ANAB ISO/IEC 17025 scope (certificate AC-1736). Techmaster only performs calibration services that are covered by our scope. For particle counter calibration, please contact your instrument’s manufacturer or its authorized service provider, and follow any service requirements they specify. If you prefer, send us your request and, with your permission, we will forward it to the manufacturer. See what is on our accredited scope.

ISO/IEC 17025 accredited · ANAB AC-1736 · San Antonio, TX

San Antonio Calibration Lab

Techmaster’s San Antonio calibration lab is at 4614 Sinclair Rd., San Antonio, TX 78222. Formerly Rothe San Antonio Calibration, it joined Techmaster in July 2025 and is ISO/IEC 17025 accredited by ANAB (certificate AC-1736). It holds our highest accredited ranges for torque (1,000 lbf·ft), high voltage (150 kV), pressure (15,000 psi) and high resistance (10 PΩ).
Address4614 Sinclair Rd.
San Antonio, TX 78222
Phone(210) 648-3133
Emailcs.sa@techmaster.us
HoursMonday to Friday, 8:00 AM to 5:00 PM local time
Techmaster San Antonio calibration lab in Texas
Techmaster San Antonio calibration lab in Texas.

What is this lab accredited for?

Everything below is on Techmaster’s ANAB ISO/IEC 17025 scope (certificate AC-1736) at this laboratory. Exact ranges and uncertainties are on our published accreditation scope.

DisciplineAccredited here
TorqueTo 1,000 lbf·ft, the highest range across Techmaster labs
High voltageDC and AC to 150 kV, the highest range across Techmaster labs
High resistance10 PΩ tera-ohmmeter; only at San Antonio
Pressure−12 psi to 15,000 psi, barometric to 39 psia
High currentAC high current to 1,500 A (San Antonio and Orlando); clamp-on to 1,025 A
DC and low-frequency electricalDC voltage to 1.1 kV, current to 1,000 A via shunts
OscilloscopesTo 600 MHz, plus wave generator
Gauge blocks and ring gagesGauge blocks to 12 in, ring gages to 6.4 in

RF and microwave, environmental chambers, vibration and 1-D/2-D dimensional calibration are not on the San Antonio scope. They are accredited at our California and Florida labs; ask us how to route those instruments. Particle counters are not on the ANAB scope at any Techmaster lab, and Techmaster does not calibrate them. Patient simulators and optical radiometers are not on the ANAB scope at any Techmaster lab either; they receive NIST-traceable certificates, not ISO/IEC 17025 accredited ones.

How do I send instruments to this location?

Customers across Texas ship instruments to the San Antonio lab. Contact us to ask about pickup, drop-off at the lab or on-site calibration. Send a model list or photos of asset tags with your quote request so the work is scheduled before the equipment arrives.

Looking for Rothe calibration? Rothe San Antonio Calibration became part of Techmaster Electronics in July 2025. Read the acquisition announcement.

For statewide coverage, see Calibration services in Texas.

Frequently asked questions

Where is Techmaster's San Antonio calibration lab?
At 4614 Sinclair Rd., San Antonio, TX 78222. Phone (210) 648-3133, email cs.sa@techmaster.us.
Is this the former Rothe San Antonio Calibration?
Yes. Rothe San Antonio Calibration joined Techmaster Electronics in July 2025 and operates as Techmaster's San Antonio laboratory.
What are the San Antonio lab's hours?
Monday to Friday, 8:00 AM to 5:00 PM Central time.
Does the San Antonio lab calibrate RF and microwave equipment?
No. RF and microwave calibration is not on the San Antonio scope. It is accredited at our Vista, Santa Clara and Orlando labs.

Other Techmaster locations

See all calibration lab locations and our accredited calibration services.

Request a Quote