Orlando Calibration Lab — Florida

May 10, 2026

Note on particle counters: This page is for general information only. Techmaster does not calibrate particle counters of any make or model, and particle counters are not on our ANAB ISO/IEC 17025 scope (certificate AC-1736). Techmaster only performs calibration services that are covered by our scope. For particle counter calibration, please contact your instrument’s manufacturer or its authorized service provider, and follow any service requirements they specify. If you prefer, send us your request and, with your permission, we will forward it to the manufacturer. See what is on our accredited scope.

ISO/IEC 17025 accredited · ANAB AC-1736 · Orlando, FL

Orlando Calibration Lab

Techmaster’s Orlando calibration lab is at 6120 Hanging Moss Road, Suite B, Orlando, FL 32807. It is ISO/IEC 17025 accredited by ANAB (certificate AC-1736) for RF and microwave to 50 GHz, environmental chambers, AC high current to 1,500 A, oscilloscopes, torque and electrical calibration, and offers free local pickup and delivery in the Orlando area.
Address6120 Hanging Moss Road, Suite B
Orlando, FL 32807
Phone407-985-5104
Emailsales.fl@techmaster.us
HoursMonday to Friday, 8:00 AM to 5:00 PM local time
Techmaster Orlando calibration lab in Florida
Techmaster Orlando calibration lab in Florida.

What is this lab accredited for?

Everything below is on Techmaster’s ANAB ISO/IEC 17025 scope (certificate AC-1736) at this laboratory. Exact ranges and uncertainties are on our published accreditation scope.

DisciplineAccredited here
RF and microwavePower sensor cal factors and SSB phase noise to 50 GHz, noise figure to 26.5 GHz
Environmental chambersTemperature and humidity chambers (Orlando and Santa Clara only)
High currentAC high current to 1,500 A (Orlando and San Antonio); clamp-on to 1,025 A
OscilloscopesLeveled sine to 2.1 GHz
TorqueTorque tools on the accredited scope
DC and low-frequency electricalDC voltage to 1.1 kV, current to 1,000 A via shunts
Pressure−12 psi to 10,000 psi, barometric to 39 psia

Vibration, 1-D/2-D dimensional and force are accredited at Santa Clara; pipettes, gauss meters and 100 kV high voltage at Vista. Particle counters are not on the ANAB scope at any Techmaster lab, and Techmaster does not calibrate them. Patient simulators and optical radiometers are not on the ANAB scope at any Techmaster lab either; they receive NIST-traceable certificates, not ISO/IEC 17025 accredited ones.

How do I send instruments to this location?

Free local pickup and delivery is available in the Orlando area. Customers elsewhere in Florida ship instruments to the lab; ask us about on-site calibration. Send a model list or photos of asset tags with your quote request so the work is scheduled before the equipment arrives.

For statewide coverage, see Calibration services in Florida.

Frequently asked questions

Where is Techmaster's Orlando calibration lab?
At 6120 Hanging Moss Road, Suite B, Orlando, FL 32807. Phone 407-985-5104, email sales.fl@techmaster.us.
What are the Orlando lab's hours?
Monday to Friday, 8:00 AM to 5:00 PM Eastern time.
Is the Orlando lab ISO/IEC 17025 accredited?
Yes. Orlando is on Techmaster's ANAB ISO/IEC 17025 scope, certificate AC-1736, for RF and microwave, environmental chambers, AC high current, oscilloscopes, torque, pressure and electrical calibration.
Do you offer pickup in Orlando?
Yes. Free local pickup and delivery is offered in the Orlando area. Contact us to schedule a collection.

Other Techmaster locations

See all calibration lab locations and our accredited calibration services.

Request a Quote