Newly Accredited Capabilities

March 7, 2025
Guide · Techmaster Electronics

Newly Accredited Capabilities

This guide from Techmaster Electronics — an ANAB-accredited ISO/IEC 17025 calibration lab — covers newly accredited capabilities: what it is, how it works, and what to look for, with practical, standards-based guidance.
ANAB accredited ISO/IEC 17025 NIST traceable

Key points

What it isA clear, jargon-free definition and the essentials.
How it worksThe working principle, explained simply.
Why it mattersWhere accuracy, safety and compliance come in.
How Techmaster helpsAccredited calibration, in-lab or on-site.

Full guide

At Techmaster, quality and accuracy have always been at the core of our operations.
As part of our ongoing commitment to excellence, we are proud to announce our New Accredited Capabilities under the ISO/IEC 17025 standard.
These newly approved ranges reflect our continuous effort to expand our technical scope and meet the growing needs of our customers.

Through each audit and capability update, we ensure that every calibration we perform meets the highest international standards.
Our team’s dedication, combined with ANAB’s oversight, guarantees that every measurement, test, and certificate we issue is both reliable and traceable.

Newly Accredited Capabilities

Maintaining Compliance Through Regular Audits

Calibration laboratories undergo regular audits by their accreditation bodies.
These audits confirm that each lab continues to meet ISO/IEC 17025 requirements.
During the review, the accreditation body checks technical competence and measurement accuracy.
They also evaluate the lab’s ability to produce precise data and maintain expert-level procedures.

2022 Audit and New Accredited Capabilities

In 2022, we successfully completed our scheduled audit in the United States.
During this evaluation, auditors reviewed both our existing qualifications and new capability ranges.
As a result, our laboratory expanded its accredited calibration capabilities across multiple disciplines.

Meeting ISO/IEC 17025 Requirements

We satisfied every general requirement related to competence, quality systems, and technical resources.
ANAB, our accrediting organization, confirmed that we operate fully under ISO/IEC 17025 standards.
Through this recognition, Techmaster continues to deliver accurate, traceable, and reliable calibration results.

Commitment to Quality and Precision

Our laboratories follow rigorous procedures to ensure accuracy in every calibration.
We perform each test under controlled conditions and issue detailed calibration certificates.
Because of this, clients can trust that their equipment meets international measurement standards.

The Audit Process in Detail

The accreditation audit process is extensive and thorough.
First, auditors review documentation and evaluate technical procedures.
Next, they conduct an on-site inspection of the laboratory’s facilities and equipment.
Finally, they verify compliance with ISO/IEC 17025, securing our accreditation renewal.

Current and Expanded Scope

Currently, our accredited scope covers calibration, dimensional measurement, and environmental testing.
In addition, we have increased our accredited ranges to include several new capabilities listed below.

  • Conductivity we can do up to 10,000 µS/cm
  • AC and DC High Voltage Measure up to 100 kV
  • AC Power Source up to 21 kW
  • Power Sensors from 9 kHz to 50 GHz
  • Protractors and Angle up to 90°
  • Thread Plug/Ring Gages up to 6.3 inches (only at Fremont)
  • Barometric Pressure Measure up to 39 psia
  • Force-Measuring Equipment Tension/Compression up to 50 kgf (NIST Class F Weights)
  • Volumetric Recipients
  • Radiation (Infrared Thermometers) up to 500 °C (TSD and TSV only)
  • Surface Plate Overall Flatness and Local Area Flatness up to 161 DL for overall and up to 0.001 inches for Local Area
  • Distance measure up to 500 inches
Thermometer Calibrator Calibration: Fix Thermal Drift
May 27, 2026 | CALIBRATORS

Metrology guide · ISO/IEC 17025 · ANAB-accredited Thermometer Calibrator Calibration Thermometer Calibrator Calibration verifies a...

Loop Calibrator Calibration: Signal Accuracy in Process Control
May 22, 2026 | CALIBRATORS

Metrology guide · ISO/IEC 17025 · ANAB-accredited Loop Calibrator Calibration Loop Calibrator Calibration verifies a...

Milliamp Calibrator Calibration in Process Control Systems
April 8, 2026 | CALIBRATORS

Metrology guide · ISO/IEC 17025 · ANAB-accredited Milliamp Calibrator Calibration Milliamp Calibrator Calibration verifies a...

Documenting Process Calibrator Calibration | Accurate & Compliant Records
December 25, 2025 | CALIBRATORS

Metrology guide · ISO/IEC 17025 · ANAB-accredited Documenting Process Calibrator Calibration… Documenting Process Calibrator Calibration...

Process Calibrator Calibration: Guide, Steps & Best Practices
December 8, 2025 | CALIBRATORS

Metrology guide · ISO/IEC 17025 · ANAB-accredited Process Calibrator Calibration Process Calibrator Calibration verifies a...

Precision Calibrator Calibration: What You Need to Know
December 4, 2025 | CALIBRATORS

Metrology guide · ISO/IEC 17025 · ANAB-accredited Precision Calibrator Calibration Precision Calibrator Calibration verifies a...

Precision vs Process vs Documenting Calibrators: What’s the Difference?
November 27, 2025 | CALIBRATORS

Guide · Techmaster Electronics Precision vs Process vs Documenting Calibrators This guide from Techmaster Electronics...

Calibrator Calibration Service for Renewable Energy Accuracy
July 30, 2025 | CALIBRATORS

Metrology guide · ISO/IEC 17025 · ANAB-accredited Calibrator Calibration Calibrator Calibration verifies a Calibrator against...

Frequently asked questions

Why does newly accredited capabilities matter for measurement accuracy?
Reliable measurements depend on well-specified, maintained and calibrated instruments; errors here flow straight into product quality, safety and compliance.
How often should related instruments be calibrated?
Most quality systems calibrate measuring instruments every 12 months, and sooner after repair or heavy use, under ISO/IEC 17025 with NIST traceability.
Can Techmaster calibrate this equipment?
Yes — Techmaster is ANAB-accredited and calibrates a wide range of instruments in-lab and on-site across the USA. Contact us for scope and a quote.

Need calibration support?

ANAB-accredited, NIST-traceable, fast turnaround — in-lab or on-site across the USA.

Contact us for a quote

References & industry standards

External standards bodies. Techmaster Electronics is an ISO/IEC 17025-accredited, NIST-traceable calibration laboratory.