Incubator Calibration: Temperature, Uniformity and CO2

November 23, 2026

Laboratory incubators hold cultures, samples and stability studies at a set temperature, and often at a set CO2 level and humidity. The display shows what the controller sensor reads at one point. The samples sit on several shelves, close to doors and walls, where the temperature can be different.

Incubator calibration checks the display against a reference and measures how evenly and steadily the chamber holds its set point.

Display accuracy

A calibrated reference probe is placed near the incubator’s own sensor, and the display is compared with it once the chamber has stabilized at each set point you use. If the controller allows an offset, it can be adjusted, and the as-found and as-left readings are both recorded.

Uniformity and stability

For the working volume, several calibrated probes or data loggers are placed across the shelves, typically at the corners and center of each level. They are logged over a set period. The results show:

  • Uniformity: the spread between the warmest and coolest positions.
  • Stability: how much each position varies over time as the controller cycles.
  • Recovery, if required: how quickly the chamber returns to set point after the door is opened.

These results tell you which shelf positions to avoid for sensitive work.

CO2 and humidity

CO2 incubators are checked at the working set point, commonly 5%, with an independent CO2 analyzer or certified gas. Sensor types behave differently: infrared sensors are stable but can be affected by humidity, while thermal conductivity sensors also respond to changes in humidity and temperature. Humidity is checked with a calibrated hygrometer where the incubator controls or displays it. See our notes on CO2 sensors.

Intervals and requalification

Annual calibration is common, with mapping repeated after relocation, major repairs or controller replacement. GMP and GLP labs often define intervals in their equipment qualification plans. For related equipment, see environmental chamber calibration and temperature probe calibration.

Accreditation and certificates

Temperature measurement is on Techmaster’s ANAB ISO/IEC 17025 scope (certificate AC-1736) within the listed ranges. CO2 and humidity checks in incubators are NIST-traceable. Tell us your set points so we can confirm what can be reported as accredited.

Frequently asked questions

How is an incubator calibrated?
The display is compared with a calibrated reference probe at each set point, and several probes or loggers map temperature uniformity and stability across the shelves.
What is incubator temperature uniformity?
The difference between the warmest and coolest positions in the working volume while the incubator holds its set point.
How is CO2 checked in an incubator?
At the working set point, commonly 5%, with an independent CO2 analyzer or certified calibration gas.
Is incubator calibration accredited at Techmaster?
Temperature measurement is on Techmaster's ANAB scope within the listed ranges; CO2 and humidity checks are NIST-traceable.