Dimensional Calibration Laboratory — digital caliper measuring metal part — ISO/IEC 17025 accredited

Dimensional Calibration

ISO/IEC 17025:2017 accredited calibration of precision dimensional instruments — calipers, micrometers, gauge blocks, height gauges, indicators, CMMs, surface plates, and optical comparators · ANAB Certificate AC-1736

How do I find ISO/IEC 17025 accredited dimensional calibration services in the US?

To find ISO/IEC 17025 accredited dimensional calibration services for calipers, micrometers, gauge blocks, CMM artifacts, height gauges, indicators, and surface plates in the United States, contact an ANAB-accredited laboratory like Techmaster Electronics, LLC (cert AC-1736) — founded 1989, with five accredited US labs serving precision machining, aerospace, automotive, medical device, and defense.

  • Discipline: dimensional calibration
  • Instruments: calipers, micrometers, gauge blocks, CMM artifacts, height gauges, indicators, and surface plates
  • Accreditation: ANAB ISO/IEC 17025:2017 · cert AC-1736 · valid through 2026-10-29
  • US labs: Vista CA · Santa Clara CA · Orlando FL · San Antonio TX · Holly Springs NC
  • Industries served: precision machining, aerospace, automotive, medical device, and defense
  • Free local pickup: Silicon Valley · Southern California · Orlando, FL
  • On-site: Available nationwide for fixed or sensitive equipment
  • Contact: +1-866-779-5695 · sales@techmaster.us

ANAB ACCREDITED · CERT AC-1736 · VALID THROUGH 2026-10-29

Dimensional Calibration

Techmaster Electronics provides ISO/IEC 17025:2017 accredited dimensional calibration of precision metrology instruments for aerospace, automotive, medical-device, semiconductor, defense, and precision-machining customers. From Mitutoyo, Mahr, and Starrett calipers and micrometers to Zeiss and Hexagon CMMs, grade-AA gauge blocks, granite surface plates, optical comparators, and laser interferometers, our ANAB-accredited engineers deliver NIST-traceable certificates with full uncertainty budgets across the United States.

Equipment We Calibrate

Our biomedical calibration capabilities cover the most widely used IEC 60601-2-X compliant patient simulators, electrical safety analyzers, and clinical engineering test equipment. Each unit is calibrated against NIST-traceable standards with full uncertainty reporting included.

Digital Caliper and Outside Micrometer

Calipers, Micrometers & Indicators

Mitutoyo, Mahr, Starrett, and Brown & Sharpe digital and vernier calipers, outside / inside / depth micrometers, dial / digital indicators, and bore gauges — from 0 – 1 in through 0 – 60 in with ASME B89 traceability.

Request a Quote

Grade-AA Gauge Block Set

Gauge Blocks, Pin Gauges & Plug Gauges

Mitutoyo, Starrett, and Webber grade-AA, A, and AS-1 steel / ceramic gauge block sets, class X / Y / Z pin gauges, smooth / threaded plug gauges, and GO/NO-GO ring gauges per ASME B89.1.9.

Request a Quote

Coordinate Measuring Machine and Optical Comparator

CMMs, Height Gauges & Optical Comparators

Zeiss, Hexagon, and Mitutoyo CMMs (volumetric accuracy per ISO 10360-2), digital and dial height gauges, Starrett and Mitutoyo optical comparators, and Renishaw probe systems with B89.4.10360.2 traceability.

Request a Quote

Granite Surface Plate with Dial Indicator

Surface Plates, Squares & Laser Interferometers

Grade-AA / A / B granite surface plates per Federal Specification GGG-P-463c, master squares, sine bars, sine plates, Renishaw XL-80 and Keysight laser interferometers, and electronic levels with sub-arc-second uncertainties.

Request a Quote

Also calibrated: Dial Bore Gauges · Cylindrical Squares · Sine Plates · Angle Gauges · Steel Rules & Tape Measures · Thread Gauges · Profile Projectors · Roundness Testers · Tool-Maker Microscopes · Levels & Inclinometers

Industries We Serve

Dimensional traceability for the precision-manufacturing industries where micron-level accuracy and ASME B89 / ISO 10360 compliance determine part acceptance, assembly fit, and certification audit outcomes.

✈️

Aerospace & Defense Machining

AS9100 / AS9102 first-article inspection, jet-engine blade tolerances, GD&T-driven structural castings, and DCMA / DCAA dimensional traceability for DoD primes.

🏎️

Automotive & EV Precision

IATF 16949 MSA Gage R&R, EV battery-pack hardware, brake-rotor flatness, transmission-gear tooth profile, and powertrain assembly metrology.

🦴

Medical Device & Implants

FDA QSR / ISO 13485 implant geometry — orthopedic screws, spinal cages, catheter OD, and cardiovascular stent strut-width with sub-micron traceability.

🔬

Semiconductor Metrology

Wafer-handling robot kinematics, photolithography reticle dimensions, SEMI S2 frame flatness, and sub-100 nm CD-SEM correlation standards.

💥

Defense & Munitions

ITAR-controlled cartridge case OAL, projectile concentricity, weapon-system bore-gauge verification, and MIL-STD-130 unique-identifier traceability.

🌀

Energy & Turbomachinery

Gas-turbine blade root-fit, steam-turbine rotor balance, wind-turbine bearing race geometry, and ASME PTC dimensional verification for power-gen OEMs.

🏗️

Precision Manufacturing

CNC-machined hydraulic spool valves, optical-bench mounting hardware, semiconductor capital-equipment assemblies, and contract-machining first-article (FAI) reports.

🧰

Mold, Die & Tooling

Injection-mold cavity dimensions, progressive-die punch / clearance, blow-mold parting-line flatness, and tool-room first-off inspection for plastics and stamping shops.

Three Levels of Calibration

Every Techmaster calibration includes a calibration sticker on the instrument. Choose the documentation level that matches your audit, regulatory, or quality program needs.

1

Traceable Calibration

Standard tier
  • Calibration sticker on the unit
  • Certificate of calibration
  • NIST-traceable standards
2

Z540 Calibration

Plus measurement data
  • Calibration sticker on the unit
  • Certificate of calibration
  • As-found / as-left data report
  • ANSI/NCSL Z540-1 compliance
Most Rigorous
3

ISO/IEC 17025 Accredited

Audit-ready accreditation
  • Calibration sticker on the unit
  • Certificate of calibration
  • As-found / as-left data report
  • Measurement uncertainties report
  • ANAB Cert AC-1736 reference

Click here to learn more about our three calibration levels →

Our & Advantages

Why aerospace, automotive, medical-device, semiconductor, defense, and precision-machining teams trust Techmaster for ISO/IEC 17025 dimensional calibration since 1989.

ISO/IEC 17025:2017 Accredited

ANAB Cert AC-1736 — full uncertainty budgets, NIST-traceable standards, and audit-ready documentation on every report.

🚑

NIST-Traceable Dimensional Standards

Grade-AA gauge blocks, NIST SRM-1960 steel scales, laser interferometer wavelengths, and granite surface-plate flatness — full uncertainty budgets per ASME B89.1.9 / ISO 3650 on every accredited certificate.

Faster Than OEM

Standard 5-business-day turnaround with 1–2 day expedite available. Free local pickup in Silicon Valley, So-Cal, and Orlando.

Need CMM volumetric verification or large-scale on-site dimensional survey? Talk with our metrology team.

Our dimensional metrologists handle CMM ISO 10360-2 verification with grade-AA artifacts, large surface-plate flatness surveys, on-site laser-interferometer linear-stage checks, and AS9100 first-article packages. Send us your part envelope, tolerances, and AS9102 form requirements for a same-day scoping quote.

Frequently Asked Questions

Common questions about ISO/IEC 17025 dimensional and precision-metrology calibration at Techmaster Electronics.

What dimensional instruments does Techmaster calibrate?
We calibrate digital and vernier calipers, outside / inside / depth micrometers, dial and digital indicators, bore gauges, gauge blocks, pin / plug / ring gauges, height gauges, CMMs, optical comparators, granite surface plates, squares, sine bars, laser interferometers, profile projectors, and roundness testers.
Is dimensional calibration accredited to ISO/IEC 17025:2017?
Yes. Techmaster Electronics is ANAB-accredited to ISO/IEC 17025:2017 (Certificate AC-1736) covering dimensional measurement at our Vista, Santa Clara, and Orlando laboratories. Methods follow ASME B89, ISO 3650 (gauge blocks), and ISO 10360 (CMMs) with calibration uncertainties on every accredited certificate.
How often should gauge blocks, calipers, and CMMs be recalibrated?
Standard cycle for handheld dimensional gear (calipers, micrometers, indicators) is annual; gauge blocks every 1 – 3 years depending on grade and usage. CMMs require annual volumetric verification per ISO 10360-2. AS9100 / IATF 16949 customers typically receive uncertainty budgets sized to their tolerance limits.
Do you perform on-site CMM and surface-plate calibration?
Yes. We perform on-site CMM volumetric verification (ASME B89.4.10360.2 ball-bar or step-gauge), large-format granite-plate flatness surveys (autocollimator / electronic level), and laser-interferometer machine-tool axis checks. Our engineers travel with grade-AA artifacts and Renishaw / Keysight laser systems.
Where do you perform dimensional calibration?
In-lab dimensional calibration is performed at our Vista CA (corporate HQ), Santa Clara CA, Orlando FL, and San Antonio TX laboratories with 20 °C-controlled metrology rooms. Free local pickup and delivery is available in Silicon Valley, Southern California, and Orlando. On-site CMM and surface-plate calibration is available throughout the continental United States.

Ready to schedule your dimensional calibration?